IGNITION DISTRIBUTOR
Data
Manufacturer
Type
Lucas part No.
Stanpart No.
Contact gap
Rotation - viewed on rotor
Firing angles
Dwell angle
Open angle
Moving contact spring tension
Capacitor capacity
Engine firing order
Centrifugal advance
Check at decelerating speeds.
ELECTRICAL
Lucas
2206
41352
217521
0·014 to 0-016 in.
Anticlockwise
60
±
1 degrees
35
±
3 degrees
25
±
3 degress
18 to 24 ozs
0·20 microfarad
1-5-3-6-2-4
Degs. distribu tor
Degs. crankshaft
Distributor
advance
Crankshaft
advance
r.p.m.
Minimum
Maximum
r.p.m.
Minimum
Maximum
Below 500
No advance to occur
Below 1000
No
advan~e
to occur
650
1'0
3-5
1300
2
7
900
6.5
9'0
1800
13
18
1100
8'5
10'5
2200
17
21
2200
12'0
14'0
4400
24
2"
2800
13'0
15'0
5600
26
30
Retard unit
Ins. of
Degs. distributor
Degs. crankshaft
retard
retard
mercury
vacuum
Minimum
Maximum
Minimum
Maximum
Below 1
No retard to occur
3
1'0
4'0
2
8
4
2'5
5'0
5
10
5
3'0
5'0
6
10
8
3'0
5'0
6
10
Triumph TR6 Manual. Part No. 545277 Issue 1