FUEL SYSTEM - TC
AIR CLEANER
- Remove and refit
19.10.01
RemO¥e
I.
Remove the six bolts securing the air cleaner
assembly to the carburetter intakes.
2.
Lift
off the air cleaner complete with gaskets.
Refitting
3.
Reverse instructions I and 2 ensuring
a)
A new gasket is fitted between the air cleaner
and carburetter intakes.
b)
The bolts are tightened evenly to 5 to 8 Ibf ft
(0·7 to 1·1 kgf m).
AIR CLEANER
- Renew elements
19.10.08
Dismantling
I.
Remove the air cleaner from the carburetter intakes
19.10.01.
2.
Remove the back plate from the cover.
3.
Remove and discard the paper elements.
4.
Examine and if unsatisfactory, discard the four
sealing rings.
5.
Clean the casing assembly.
Re-assembling
6.
Place two sealing rings in position on the back plate
location.
7.
Position the new paper elements on the back plate
ensuring that they locate properly.
8.
Position remaining two sealing rings on the cover
locations and place the cover over the back plate.
Ensure that the elements locate correctly.
9.
Refit the air cleaner 19.10.01.
19.10.0IC
19.1O.08C
Triumph TR6 Manual. Pan No. 545277 Issue I