Triumph TR6 PI Operation Manual page 33

Table of Contents

Advertisement

MAINTENANCE
(9) Renew oil filter element
See 12.60.01 and 12.60.08.
(I
0)
Clean fuel pump sediment bowl
See 19.45.05
(II) Lubricate distributor and check automatic advance
Lubricate distributor - See 86.35.18
Check automatic advance
I.
Fit a strobe Timing Light in accordance with the
Timing Light manufacturers instructions.
2.
Disconnect vacuum pipe between distributor and
induction side of engine.
3.
Start engine.
Check centr(fugal advance.
4.
Using a second operator to vary engine speed, check
apparent movement of timing marks under strobe
light.
5.
Reconnect vacuum pipe.
Check vacuum advance
6.
Repeat the procedure in 4 above, comparing engine
timing with and without vacuum pipe connected.
7.
Stop engine.
NOTE: If more accurate results are required electronic
tuning equipment may be used in conjuncIion with
the data
01)
page 86.35.00. This is extra to normal
service requirements.
10.00.08
Triumph TR6 Manual. Part
No.
545277 Issue 1
~
~

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tr6 tc

Table of Contents