Adjusting operating lever
5.
Slacken clamp bolt on operating lever.
6.
Check, ignition ON, top gear, overdrive IN.
7-.
Position rod through hole in setting lever and
alignment hole in case. Push plunger into solenoid to
its limit, holding lever fork against collar of plunger.
8.
Tighten clamp bolt on operating rod.
9.
Switch off, re-check 4 till condition
4a
exists.
10.
Adjust the stop to provide 0;0625 in (I '6 mm) free
movement by slackening locknut and turning grub
screw with an Allen key.
Testing
1.
Raise vehicle.
2.
Connect an ammeter into solenoid feed circuit.
3.
Switch ignition ON, top gear, overdrive IN.
4.
Note and act on the following accordingly.
0..
The setting lever will move to a position where
its alignment hole is coincident with a hole in
the casing (test alignment) by inserting a rod
3/16" dia. through hole in lever and into casing
hole). The ammeter will drop to holding current
of 1 to 2 amps immediately after switching on.
Test satisfactory.
b.
No current to solenoid - check circuit.
c.
Setting lever correctly aligned, ammeter reading
hign - renew solenoid. 40.22.14.
d
Setting lever incorrectly aligned, ammeter
reading correct/incorrect -
adjust operating
lever.
SOLENOID
- Test and adjust
40.22.01
OVERDRIVE 'A' TYPE