Refitting
7.
Fit the needle valve and renew the washer.
8.
Fit the float assembly.
9.
Check and if necessary, adjust the height of both
floats. Instruction 5, 19.15.32.
10.
Renew the gasket and refit the float chamber.
II.
Refit the carburetters.
Removing
1.
Remove the carburetters 19.15.11.
2.
Remove the six screws securing the float chamber to
the body.
3.
Remove the float chamber.
4.
Remove the gasket.
5.
Remove the float assembly by gently prising the
spindle from the locating clips.
6.
Remove the needle valve and washer.
FLOAT CHAMBER NEEDLE VALVE
- Remove and refit
FLOAT CHAMBER LEVELS
- Check and adjust
19.15.24
19.15.32
FUEL SYSTEM - TC
Check
1.
Remove the carburetters 19.15.11.
2.
Remove the six screws securing the float chamber to
the body.
3.
Remove the float chamber.
4.
Remove the gasket.
5.
With the carburetter in the inverted position check
the distance between the gasket face on the
carburetter body to the highest point of each float.
NOTE: The height of both floats must be the same Le.
0'625 to 0'627 in (16 to 17 mm).
Adjust
6.
Bend the tab that contacts the needle valve but
ensure that it sits at right angles to the valve to
prevent the possibility of sticking.
7.
Fit a new gasket and reverse instructions I to 3.
Triumph TR6 Manua"1. Part No. 545277 Issue 1
V
~)f;1
LIII
19.15.24C
19.15.32C