Multiline Terminal Function D1 - NEC UNIVERGE SV9100 System Maintenance Manual

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

Issue 1.0
Perform Multiline Terminal Self Test:
1. Unplug terminal line cord.
2. Hold down  and # together and plug in the line cord.
3. Press each terminal key to test tones, LEDs, and key contacts.
4. Return terminal on-line by taking handset off-hook and then
return to on-hook.
Reset and test. Replace defective
terminal, and test.
Send terminal
in for repair.
Send GCD-8DLCA in for
repair.
2 - 12
Multiline Terminal Function Problems
All
terminals?
No
Check PRG 10-03-01for
correct Station Assignment.
No
Assignment
correct?
Yes
No
Yes
Problem
solved?
Reset and test. Replace
faulty GCD-8DLCA.
Yes
Problem
solved?
D1
Yes
Go to Flowchart A2.
No
Connect terminal directly
to MDF, and test.
No
Problem
solved?
1. Perform Second Initialization, and test.
No
2. Perform First Initialization, and test.
3. Replace GCD-CP10, and test using
default program.
UNIVERGE SV9100
Reassign.
Yes
Problem
solved?
Yes
Replace station cable.
End.

Advertisement

Table of Contents
loading

Table of Contents