active-hold-delay
Syntax
active-hold-delay active-hold-delay
no active-hold-delay
Context
config>service>epipe>endpoint
This command specifies that the node will delay sending the change in the T-LDP status bits for the
Description
VLL endpoint when the MC-LAG transitions the LAG subgroup which hosts the SAP for this VLL
endpoint from active to standby or when any object in the endpoint. For example, SAP, ICB, or
regular spoke SDP, transitions from up to down operational state.
By default, when the MC-LAG transitioned the LAG subgroup which hosts the SAP for this VLL
endpoint from active to standby, the node sends immediately new T-LDP status bits indicating the
new value of "standby" over the spoke SDPs which are on the mate-endpoint of the VLL. The same
applies when any object in the endpoint changes an operational state from up to down.
There is no delay applied to the VLL endpoint status bit advertisement when the MC-LAG transitions
the LAG subgroup which hosts the SAP from "standby" to "active" or when any object in the
endpoint transitions to an operationally up state.
0 — A value of zero means that when the MC-LAG transitioned the LAG subgroup which hosts the
Default
SAP for this VLL endpoint from active to standby, the node sends immediately new T-LDP status
bits indicating the new value of standby over the spoke SDPs which are on the mate-endpoint of the
VLL. The same applies when any object in the endpoint changes an operational state from up to
down.
active-hold-delay — Specifies the active hold delay in 100s of milliseconds.
Parameters
revert-time
Syntax
revert-time [revert-time | infinite]
no revert-time
Context
config>service>epipe>endpoint
This command configures the time to wait before reverting back to the primary spoke SDP defined on
Description
this service endpoint, after having failed over to a backup spoke SDP.
revert-time — Specify the time, in seconds, to wait before reverting to the primary SDP.
Parameters
infinite — Causes the endpoint to be non-revertive.
standby-signaling-master
Syntax
[no] standby-signaling-master
Context
config>service>vll>endpoint