Figure 26: Vll Resilience With Pseudowire Switching - Alcatel-Lucent 7210 SAS M Service Manual

Hide thumbs Also See for 7210 SAS M:
Table of Contents

Advertisement

Pseudowire Switching
VLL Resilience for a Switched PW Path
Figure 26
configuration follows.
sap 1/1/1:100
Configuration
T-PE1
configure service epipe 1
endpoint X
exit
endpoint Y
revert-time 100
standby-signaling-master
exit
sap 1/1/1:100 endpoint X
spoke-sdp 1:100 endpoint Y
spoke-sdp 2:200 endpoint Y
spoke-sdp 3:300 endpoint Y
T-PE2
configure service epipe 1
endpoint X
exit
endpoint Y
revert-time 100
Page 152
displays a VLL resilience for a switched pseudowire path example. A sample
spoke-sdp 1:100
T-PE 1
spoke-sdp 2:200
spoke-sdp 3:300

Figure 26: VLL Resilience with Pseudowire Switching

precedence primary
precedence 1
precedence 1
S-PE 1
spoke-sdp 4:400
spoke-sdp 5:500
S-PE 2
spoke-sdp 6:600
S-PE 3
7210 SAS M Services Guide
sap 2/2/2:200
T-PE 2