Configuring a VLL Service with CLI
Configuring VLL Resilience for a Switched Pseudowire Path
Note that the 7210 SAS M only supports T-PE functionality.
sap 1/1/1:100
T-PE1
The following displays an example for the configuration on TPE1.
*A:ALA-48>config>service>epipe# info
----------------------------------------------
----------------------------------------------
*A:ALA-48>config>service>epipe#
Page 194
spoke-sdp 1:100
spoke-sdp 2:200
T-PE-1
spoke-sdp 3:300
Figure 34: VLL Resilience with Pseudowire Switching
endpoint "x" create
exit
endpoint "y" create
exit
sap 1/1/1:100 endpoint "x" create
exit
spoke-sdp 1:100 endpoint "y" create
precedence primary
exit
spoke-sdp 2:200 endpoint "y" create
precedence 1
exit
spoke-sdp 3:300 endpoint "y" create
precedence 1
exit
no shutdown
S-PE-1
sap 1/2/1:100
spoke-sdp 4:400
S-PE-2
spoke-sdp 6:600
S-PE-3
7210 SAS M Services Guide
T-PE-2
OSSG247