show diagnostics

show diagnostics slot [<slot> | A | B]
Description
Displays the status of the last diagnostic test run on the switch.
Syntax Description
slot
A | B
Default
N/A.
Usage Guidelines
Use this command to display information from the last diagnostic test run on the switch. The following
switch diagnostics information is displayed:
• Slot number
• Result of the test (pass/fail)
• Date the test was run
• Date the test last failed (if the test has never failed,
• Summary of the test (Diagnostics pass/Diagnostics fail)
In addition to the previous information, if the test passes, the day, month, date, year, and time of the
diagnostic test is displayed.
Running Diagnostics on Modules. To run diagnostics on an I/O module or an MSM, use the
following command:
run diagnostics [extended | normal] slot [<slot> | A | B]
Depending on the software version running on your switch, additional or different diagnostics
information might be displayed. For more information, see "run diagnostics" on page 955.
Example
The following command displays the results of module diagnostics for the I/O module in slot 1:
show diagnostics slot 1
The following is sample output from this command:
Slotnum 1
DiagResult timestamp Thu Jun 24 23:57:00 2004
Test Temperature = 34 degrees C
Diag Test Version=1.0.3.1.
ExtremeWare XOS 11.0 Command Reference Guide
Specifies the slot number of an I/O module. I/O modules are installed in slots
1 through 8.
Specifies the MSM. A specifies the MSM installed in slot A. B specifies the
MSM installed in slot B.
Never
S/N=
is displayed)