Commands for Status Monitoring and Statistics
configure log target severity
configure log target [console | memory-buffer | nvram | primary-msm |
backup-msm | session | syslog [<all | ipaddress> {vr <vr_name>} [local0 ...
local7]]] {severity <severity> {only}}
Description
Sets the severity level of messages sent to the target.
Syntax Description
console
memory-buffer
nvram
primary-msm
backup-msm
session
syslog
all
ipaddress
vr_name
local0 ... local7
severity
only
Default
By default, targets are sent messages of the following severity level and above:
• console display—info
• memory buffer—debug-data
• NVRAM—warning
• session—info
• syslog—debug-data
• primary MSM—error
• backup MSM—error
If a virtual router is not specified, VR-Mgmt is used.
Usage Guidelines
This command configures the specified target with a severity level. The filter associated with the target
is not affected. A message is sent to a target if the target has been enabled, the message passes the
associated filter, the message is at least as severe as the configured severity level, and the message
output matches the regular expression specified.
See the command
show log
328
Specifies the console display.
Specifies the switch memory buffer.
Specifies the switch NVRAM.
Specifies the primary MSM.
Specifies the backup MSM.
Specifies the current session (including console display).
Specifies a syslog target.
Specifies all of the remote syslog servers.
Specifies the syslog IP address.
Specifies the virtual router that can reach the server IP address.
Specifies the local syslog facility.
Specifies the least severe level to send (if the keyword only is omitted).
Specifies that only the specified severity level is to be sent.
on page 364 for a detailed description of severity levels.
ExtremeWare XOS 11.0 Command Reference Guide