Commands for Status Monitoring and Statistics

show fans

show fans {detail}
Description
Displays the status of the fans in the system.
Syntax Description
detail
Default
N/A.
Usage Guidelines
Use this command to view detailed information about the health of the fans.
This status information may be useful for your technical support representative if you have a network
problem.
The following fan information is collected by the switch:
• State—The current state of the power supply. Options are:
— Empty: There is no fan installed.
— Failed: The fan failed.
— Operational: The fan is installed and working normally.
• NumFan—The number of fans in the fan tray.
• PartInfo—Information about the fan tray including the:
— Serial number, a collection of numbers and letters, that make up the serial number of the fan.
— Part number, a collection of numbers and letters, that make up the part number of the fan.
• Revision—The revision number of the fan.
• FailureCode—Specifies the diagnostic failure code of the fan.
• Odometer—Specifies the power-on date and how long the fan tray has been operating since it first
powered-on.
• Temperature—Specifies, in celsius, the current temperature of the fan.
• Fan Name—Specifies the individual state for each fan in a fan tray and its current speed in round
per minutes (rpm).
Example
The following command displays the status of the installed fans. If a fan is not installed, the state of the
fan is
.
Empty
show fans
360
The detail option is reserved for future use.