Port-Security Timer Disableport; Port-Security Trap - 3Com S7906E Command Reference Manual

6300 series
Hide thumbs Also See for S7906E:
Table of Contents

Advertisement

[Sysname-GigabitEthernet2/0/1] undo port-security port-mode
[Sysname-GigabitEthernet2/0/1] port-security port-mode userlogin

port-security timer disableport

Syntax
port-security timer disableport time-value
undo port-security timer disableport
View
System view
Default Level
2: System level
Parameters
time-value: Silence timeout during which the port remains disabled, in seconds. It ranges from 20 to
300.
Description
Use the port-security timer disableport command to set the silence timeout during which the port
remains disabled.
Use the undo port-security timer disableport command to restore the default.
By default, the silence timeout is 20 seconds.
If you configure the intrusion protection policy as disabling the port temporarily whenever it receives an
illegal frame, you can use this command to set the silence period.
Related commands: display port-security.
Examples
# Configure the intrusion protection policy as disabling the port temporarily whenever it receives an
illegal frame and set the silence timeout to 30 seconds.
<Sysname> system-view
[Sysname] port-security timer disableport 30
[Sysname] interface gigabitethernet 2/0/1
[Sysname-GigabitEthernet2/0/1] port-security intrusion-mode disableport-temporarily

port-security trap

Syntax
port-security trap { addresslearned | dot1xlogfailure | dot1xlogoff | dot1xlogon | intrusion |
ralmlogfailure | ralmlogoff | ralmlogon }
undo port-security trap { addresslearned | dot1xlogfailure | dot1xlogoff | dot1xlogon | intrusion |
ralmlogfailure | ralmlogoff | ralmlogon }