View
System view
Default Level
2: System level
Parameters
number: Maximum number of the tests that the NQA client can simultaneously perform, in the range 1 to
5. The default value is 2.
Description
Use the nqa agent max-concurrent command to configure the maximum number of tests that the NQA
client can simultaneously perform.
Use the undo nqa agent max-concurrent command to restore the default.
From the beginning to the end of a test, the NQA test is in the test status; from the end of a test to the
beginning of the next test, the NQA test is in the waiting status.
Examples
# Configure the maximum number of the tests that the NQA client can simultaneously perform as 5.
<Sysname> system-view
[Sysname] nqa agent max-concurrent 5

nqa schedule

Syntax
nqa schedule admin-name operation-tag start-time now lifetime forever
undo nqa schedule admin-name operation-tag
View
System view
Default Level
2: System level
Parameters
admin-name: Specifies the name of the administrator who creates the NQA test operation, a string of 1
to 32 characters. It is case-insensitive.
operation-tag: Specifies the test operation tag, a string of 1 to 32 characters. It is case-insensitive.
now: Specifies to start the test for a test group immediately.
forever: Specifies that the test is performed for a test group forever.
Description
Use the nqa schedule command to configure the test start time and test period for a test group.
Use the undo nqa schedule command to stop the test for the test group.
Note that: