mmu-monitor enable

Syntax
mmu-monitor enable slot-number
undo mmu-monitor enable slot-number
View
System view
Default Level
2: System level
Parameters
slot-number: Slot number of a board. The value range varies with devices.
Description
Use the mmu-monitor enable command to enable expansion memory data recovery function on a
board. After this function is enabled, data monitoring of the expansion memory on the specified EA LPU
or LSQ1SRP1CB SRPU is performed. When data error occurs, data recovery will start automatically.
Use the undo mmu-monitor enable command to disable the function.
By default, data recovery function of the expansion memory is enabled.
Examples
# Disable the expansion memory data recovery function on the EA LPU in slot 1.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] undo mmu-monitor enable 1
reboot
Syntax
reboot [ slot slot-number ]
View
User view
Default Level
2: System level
Parameters
slot slot-number: Specifies the slot number of a board. The value range varies with devices.
Description
Use the reboot command to reboot a board, or the whole system.