Examples
# Configure the interval for sending packets in a probe in a UDP-jitter test as 100 milliseconds.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type udp-jitter
[Syaname-nqa-admin-test-udp-jitter] probe packet-interval 100

probe packet-number

Syntax
probe packet-number packet-number
undo probe packet-number
View
UDP-jitter test type view
Default Level
2: System level
Parameters
packet-number: Number of packets sent in a UDP-jitter test, in the range 10 to 1000.
Description
Use the probe packet-number command to configure the number of packets sent in a UDP-jitter
probe.
Use the undo probe packet-number command to restore the default.
By default, the number of packets sent in a probe is 10.
Examples
# Configure the number of packets sent in a UDP-jitter probe as 100.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type udp-jitter
[Syaname-nqa-admin-test-udp-jitter] probe packet-number 100

probe packet-timeout

Syntax
probe packet-timeout packet-timeout
undo probe packet-timeout
View
UDP-jitter test type view
Default Level
2: System level