<Sysname> display channel 0
channel number:0, channel name:console
MODU_ID
NAME
ffff0000 default
Table 1-2 display channel command output description
Field
channel number
channel name
MODU_ID
NAME
ENABLE
LOG_LEVEL
ENABLE
TRAP_LEVEL
ENABLE
DEBUG_LEVEL
The above information indicates to output log information with the severity from 0 to 4, trap information
with the severity from 0 to 7 and debugging information with the severity from 0 to 7 to the console. The
information source modules are all modules (default).

display info-center

Syntax
display info-center
View
Any view
Default Level
1: Monitor level
Parameters
None
ENABLE LOG_LEVEL
Y
warnings
A specified channel number, in the range 0 to 9.
A specified channel name, which varies with user's configuration.
For more information, refer to the info-center channel name
command.
The ID of the module to which the information permitted to pass
through the current channel belongs
The name of the module to which the information permitted to pass
through the current channel belongs
Default means all modules are allowed to output system
information, but the module type varies with devices.
Indicates whether to enable or disable the output of log
information, which could be Y or N.
The severity of log information, refer to
Indicates whether to enable or disable the output of trap
information, which could be Y or N.
The severity of trap information, refer to
Indicates whether to enable or disable the output of debugging
information, which could be Y or N.
The severity of debugging information, refer to
details.
ENABLE TRAP_LEVEL
Y
debugging
Description
1-2
ENABLE DEBUG_LEVEL
Y
debugging
Table 1-4
for details.
Table 1-4
for details.
Table 1-4
for