Use the display poe-power ac-input state command to display the state information of the AC input
power.
Examples
# Display the state information of the AC input power.
<Sysname> display poe-power ac-input state
Module Number
Output AC Current A Alarm
Output AC Current B Alarm
Output AC Current C Alarm
Module 1:
Volt Phase AB Alarm
Volt Phase BC Alarm
Volt Phase CA Alarm
Module 2:
Volt Phase AB Alarm
Volt Phase BC Alarm
Volt Phase CA Alarm
Table 1-10 display poe-power ac-input state command output description
Module Number
Output AC Current A/B/C Alarm
Volt Phase AB/BC/CA Alarm
: 2
: Normal
: Under Limit
: Lack Phase
: Above Limit
: Fuse Broken
: Switch Off
: Above Limit
: Fuse Broken
: Switch Off
Field
Number of modules that a power supply unit (PSU) contains
Output three-phase AC voltage state:
AC voltage input state: Same as those of the output
three-phase AC current
Description
Normal: The voltage is normal.
Under Limit: The voltage is below the lower limit.
Above Limit: The voltage is above the upper limit.
Lack Phase: A phase is lost.
Fuse Broken: The fuse is broken.
Switch Off: The switch is turned off.
Other Error: Other faults