Examples
# Configure the system to output information to the trap buffer through the default channel, and set the
trap buffer size to 30.
<Sysname> system-view
[Sysname] info-center trapbuffer size 30
logfile save
Syntax
logfile save
View
Any view
Default Level
2: System level
Parameters
None
Description
Use the logfile save command to save all the contents in the logfile buffer into the log file.
By default, the system automatically saves the log file based on a frequency configured by the
info-center logfile frequency command into a directory configured by the info-center logfile
switch-directory command.
Note that all contents in the logfile buffer will be cleared after they are successfully saved into the log file
automatically or manually.
By default, the log file is automatically saved to the logfile directory under root directory of the CF card
(cf:/logfile). If there is no CF card, you can use the info-center logfile switch-directory command to
configure the directory where a log file is saved, otherwise, the system will prompt you that the save
operation failed.
Examples
# Save the contents in the logfile buffer into the log file.
<Sysname> logfile save
reset logbuffer
Syntax
reset logbuffer
1-25
Need help?
Do you have a question about the S7906E and is the answer not in the manual?