Default Level
2: System level
Parameters
signal: Specifies the PoE mode as signal (power over signal cables).
spare: Specifies the PoE mode as spare (power over spare cables).
Description
Use the poe mode command to configure a PoE mode.
Use the undo poe mode command to restore the default.
By default, the PoE mode is signal (power over signal cables).
The PSE supplies power for a PoE interface in the following two modes: signal and spare.
In the signal mode, lines in Category 3 and 5 twisted pair cables used for transmitting data are
also used for supplying DC power.
In the spare mode, lines in Category 3 and 5 twisted pair cables not in use are used for supplying
DC power.
Examples
# Set the PoE mode to signal (power over signal cables).
<Sysname> system-view
[Sysname] interface ethernet 2/0/1
[Sysname-Ethernet2/0/1] poe mode signal
# Set the PoE mode to signal (power over signal cables) through a PoE configuration file.
<Sysname> system-view
[Sysname] poe-profile abc
[Sysname-poe-profile-abc-1] poe mode signal
[Sysname-poe-profile-abc-1] quit
[Sysname] interface ethernet 2/0/1
[Sysname-Ethernet2/0/1] apply poe-profile name abc

poe pd-description

Syntax
poe pd-description string
undo poe pd-description
View
PoE interface view
Default Level
2: System level
Parameters
string: Description of the PD connected to a PoE interface, a string of 1 to 80 characters.