19.5.6 LEUARTn_SIGFRAME - Signal Frame Register (Async Reg)
For more information about asynchronous registers see
Offset
0x014
Reset
Access
Name
Bit
Name
31:9
Reserved
8:0
SIGFRAME
When a frame matching SIGFRAME is detected by the receiver, SIGF interrupt flag is set.
19.5.7 LEUARTn_RXDATAX - Receive Buffer Data Extended Register (Actionable Reads)
Offset
0x018
Reset
Access
Name
Bit
Name
31:16
Reserved
15
FERR
Set if data in buffer has a framing error. Can be the result of a break condition.
14
PERR
Set if data in buffer has a parity error.
13:9
Reserved
8:0
RXDATA
Use this register to access data read from the LEUART. Buffer is cleared on read access.
silabs.com | Building a more connected world.
LEUART - Low Energy Universal Asynchronous Receiver/Transmitter
4.3 Access to Low Energy Peripherals (Asynchronous
Reset
Access
Description
To ensure compatibility with future devices, always write bits to 0. More information in
tions
0x000
RW
Signal Frame
Reset
Access
Description
To ensure compatibility with future devices, always write bits to 0. More information in
tions
0
R
Receive Data Framing Error
0
R
Receive Data Parity Error
To ensure compatibility with future devices, always write bits to 0. More information in
tions
0x000
R
RX Data
Bit Position
Bit Position
Reference Manual
Registers).