Bit
Name
4
5
6
7
8
9
10
11:8
Reserved
7:4
STEADYTIMEOUT
Wait duration depends on the chosen XTAL (expected value is around 100 us). Program the desired duration measured in
cycles of (at least) 83 ns.
Value
0
1
2
3
4
5
6
7
8
9
10
3:0
STARTUPTIMEOUT
Wait duration depends on the chosen XTAL (expected value is between 100 us and 1600 us). Program the desired duration
measured in cycles of (at least) 83 ns.
Value
0
1
2
3
4
5
6
7
8
silabs.com | Building a more connected world.
Reset
Access
Description
256CYCLES
Timeout period of 256 cycles
1KCYCLES
Timeout period of 1024 cycles
2KCYCLES
Timeout period of 2048 cycles
4KCYCLES
Timeout period of 4096 cycles
8KCYCLES
Timeout period of 8192 cycles
16KCYCLES
Timeout period of 16384 cycles
32KCYCLES
Timeout period of 32768 cycles
To ensure compatibility with future devices, always write bits to 0. More information in
tions
0x6
RW
Wait Duration in HFXO Startup Steady Wait State
Mode
Description
2CYCLES
Timeout period of 2 cycles
4CYCLES
Timeout period of 4 cycles
16CYCLES
Timeout period of 16 cycles
32CYCLES
Timeout period of 32 cycles
256CYCLES
Timeout period of 256 cycles
1KCYCLES
Timeout period of 1024 cycles
2KCYCLES
Timeout period of 2048 cycles
4KCYCLES
Timeout period of 4096 cycles
8KCYCLES
Timeout period of 8192 cycles
16KCYCLES
Timeout period of 16384 cycles
32KCYCLES
Timeout period of 32768 cycles
0x7
RW
Wait Duration in HFXO Startup Enable Wait State
Mode
Description
2CYCLES
Timeout period of 2 cycles
4CYCLES
Timeout period of 4 cycles
16CYCLES
Timeout period of 16 cycles
32CYCLES
Timeout period of 32 cycles
256CYCLES
Timeout period of 256 cycles
1KCYCLES
Timeout period of 1024 cycles
2KCYCLES
Timeout period of 2048 cycles
4KCYCLES
Timeout period of 4096 cycles
8KCYCLES
Timeout period of 8192 cycles
Reference Manual
CMU - Clock Management Unit
1.2 Conven-
Rev. 1.1 | 320
Need help?
Do you have a question about the EFR32xG14 Wireless Gecko and is the answer not in the manual?