Bit
Name
Value
0
1
7
FULLIEN
Enable/Disable FIFO full interrupt.
6
APT4096IEN
Enable/Disable 4096-sample Adaptive Proportion test failure interrupt.
5
APT64IEN
Enable/Disable 64-sample Adaptive Proportion test failure interrupt.
4
REPCOUNTIEN
Enable/Disable Repetition Count Test failure interrupt.
3
CONDBYPASS
Enables bypassing of the conditioning function (to observe entropy source directly).
Value
0
1
2
TESTEN
Selects the input for the conditioning function and continuous tests.
Value
0
1
1
Reserved
0
ENABLE
Enable the TRNG. The module will generate random numbers unless the FIFO is full.
Value
0
1
silabs.com | Building a more connected world.
Reset
Access
Description
Mode
Description
NORMAL
Module not in reset
RESET
The continuous test, the conditioning function and the FIFO are reset
0
RW
Interrupt Enable for FIFO Full
0
RW
Interrupt Enable for Adaptive Proportion Test Failure (4096-sample
Window)
0
RW
Interrupt Enable for Adaptive Proportion Test Failure (64-sample
Window)
0
RW
Interrupt Enable for Repetition Count Test Failure
0
RW
Conditioning Bypass
Mode
Description
NORMAL
The conditionig function is used
BYPASS
The conditioning function is bypassed
0
RW
Test Enable
Mode
Description
NOISE
Non-determinsitc random number generation
TESTDATA
Pseudo-random number generation
To ensure compatibility with future devices, always write bits to 0. More information in
tions
0
RW
TRNG Module Enable
Mode
Description
DISABLED
Module disabled
ENABLED
Module enabled
TRNG - True Random Number Generator