Cryotimer_Periodsel - Interrupt Duration - Silicon Laboratories EFR32xG14 Wireless Gecko Reference Manual

Table of Contents

Advertisement

22.5.2 CRYOTIMER_PERIODSEL - Interrupt Duration

Offset
0x004
Reset
Access
Name
Bit
Name
31:6
Reserved
5:0
PERIODSEL
Defines the duration between the Interrupts/Wakeup events based on the pre-scaled clock.
Value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
silabs.com | Building a more connected world.
Reset
Access
Description
To ensure compatibility with future devices, always write bits to 0. More information in
tions
0x20
RW
Interrupts/Wakeup Events Period Setting
Description
Wakeup event after every Pre-scaled clock cycle.
Wakeup event after 2 Pre-scaled clock cycles.
Wakeup event after 4 Pre-scaled clock cycles.
Wakeup event after 8 Pre-scaled clock cycles.
Wakeup event after 16 Pre-scaled clock cycles.
Wakeup event after 32 Pre-scaled clock cycles.
Wakeup event after 64 Pre-scaled clock cycles.
Wakeup event after 128 Pre-scaled clock cycles.
Wakeup event after 256 Pre-scaled clock cycles.
Wakeup event after 512 Pre-scaled clock cycles.
Wakeup event after 1k Pre-scaled clock cycles.
Wakeup event after 2k Pre-scaled clock cycles.
Wakeup event after 4k Pre-scaled clock cycles.
Wakeup event after 8k Pre-scaled clock cycles.
Wakeup event after 16k Pre-scaled clock cycles.
Wakeup event after 32k Pre-scaled clock cycles.
Wakeup event after 64k Pre-scaled clock cycles.
Wakeup event after 128k Pre-scaled clock cycles.
Wakeup event after 256k Pre-scaled clock cycles.
Wakeup event after 512k Pre-scaled clock cycles.
Wakeup event after 1M Pre-scaled clock cycles.
Wakeup event after 2M Pre-scaled clock cycles.
Wakeup event after 4M Pre-scaled clock cycles.
CRYOTIMER - Ultra Low Energy Timer/Counter
Bit Position
Reference Manual
1.2 Conven-
Rev. 1.1 | 750

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EFR32xG14 Wireless Gecko and is the answer not in the manual?

Questions and answers

Table of Contents