28.5.11 LESENSE_STATUS - Status Register (Async Reg)

For more information about asynchronous registers see
Offset
0x028
Reset
Access
Name
Bit
Name
31:6
Reserved
5
DACACTIVE
LESENSE is currently using the VDAC.
4
SCANACTIVE
LESENSE is currently interfacing to sensors.
3
RUNNING
LESENSE is running in periodic mode.
2
BUFFULL
Set when the result buffer is full
1
BUFHALFFULL
Set when the result buffer is half full
0
BUFDATAV
Set when data is available in the result buffer. Cleared when the buffer is empty.
silabs.com | Building a more connected world.
4.3 Access to Low Energy Peripherals (Asynchronous
Reset
Access
Description
To ensure compatibility with future devices, always write bits to 0. More information in
tions
0
R
LESENSE VDAC Interface is Active
0
R
LESENSE Scan Active
0
R
LESENSE Periodic Counter Running
0
R
Result Buffer Full
0
R
Result Buffer Half Full
0
R
Result Data Valid