Alarm value (r2124, format):
The alarm value specifies additional, more precise information about an alarm.
The alarm value is entered in the alarm buffer in r2124[0...63] and specifies additional, more
precise information about an alarm.
Remedy:
Describes the methods available for eliminating the cause of the active fault or alarm.
On a case for case basis, service and maintenance personnel are responsible for choosing
a suitable method for eliminating the cause of faults.
4.1.3
Number ranges of faults and alarms
Note
The following number ranges represent an overview of all faults and alarms used in the
SINAMICS drive family.
The faults and alarms for the product described in this List Manual are described in detail in
"List of faults and alarms (Page 1003)".
Faults and alarms are organized into the following number ranges:
Table 4-5
SINAMICS G120 CU250S-2 Control Units
List Manual, 09/2017, A5E33842890
WARNING
Number ranges of faults and alarms
of
To
1000
3999
4000
4999
5000
5999
6000
6899
6900
6999
7000
7999
8000
8999
9000
12999
13000
13020
13021
13099
13100
13102
13103
19999
20000
29999
30000
30999
31000
31999
Control Unit
Reserved
Power section
Infeed
Braking Module
Drive
Option Board
Reserved
Licensing
Reserved
Know-how protection
Reserved
OEM
DRIVE-CLiQ component power unit
DRIVE-CLiQ component encoder 1
4 Faults and alarms
4.1 Overview of faults and alarms
Area
1001