Configuring Related Parameters Of Ethernet Cfm - Huawei Quidway S3700 Series Configuration Manual

Hide thumbs Also See for Quidway S3700 Series:
Table of Contents

Advertisement

Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
Level
MA Name
MEP ID
Vlan ID
VSI Name
Interface Name
CCM Send
Direction
MAC Address
Run the display cfm remote-mep command. If information about the RMEP is displayed, it
indicates that the configuration is successful.
<Quidway> display cfm remote-mep
The total number of RMEPs is : 2
The status of RMEPS : 2 up, 0 down, 0 disable
--------------------------------------------------
MD Name
Level
MA Name
RMEP ID
Vlan ID
VSI Name
MAC
CCM Receive
Trigger-If-Down
CFM Status
Alarm Status
MD Name
Level
MA Name
RMEP ID
Vlan ID
VSI Name
MAC
CCM Receive
Trigger-If-Down
CFM Status
Alarm Status
In IEEE 802.1ag Draft 7, run the display mip create-type command. If the MIP creation rule
is correct, the configuration is successful.
<Quidway> display mip create-type interface ethernet0/0/1
Interface Name
---------------------------------------------------------------------------
GigabitEthernet0/0/1
Run the display cfm mip command. If information about the MIP is displayed, the configuration
is successful.
<Quidway> display cfm mip
Interface Name
-----------------------------------
Ethernet0/0/1

4.9 Configuring Related Parameters of Ethernet CFM

By adjusting parameters of Ethernet CFM, you can detect connectivity of an Ethernet network
from end to end.
Issue 01 (2011-10-26)
: 0
: ma1
: 11
: 221
: --
: Ethernet0/0/1
: disabled
: inward
: 0018-2000-0083
: md2
: 7
: ma3
: 110
: 20
: --
: 0000-0121-0222
: enabled
: disabled
: up
: None
: md2
: 4
: ma3
: 30
: --
: --
: --
: enabled
: disabled
: up
: None
MIP Create-Type
none
Level
0
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Ethernet OAM Configuration
MIP Create-Type On Interface
--
186

Advertisement

Table of Contents
loading