Procedure For Replacing Finisher Pwb; Replacement Procedure - Riso ComColor X1 series Technical Manual

Hide thumbs Also See for ComColor X1 series:
Table of Contents

Advertisement

5. Procedure for replacing Finisher PWB

5-1. Replacement procedure

• Since the Finisher NVM data (parameters set in the Test Mode data setting) is stored in the Finisher PWB,
it is necessary to save and restore the setting data for the replacement of the Finisher PWB.
If it is not possible to save the NVM data, after the PWB is replaced, enter the data manually in the Test Mode by
referring to the NVM setting list provided with the product.
To initialize the NVM data in the Finisher PWB, select Test Mode No. 4500
AREA INITIALIZE" → and then enter "79747".
(1) Before replacing the Finisher PWB, select Test Mode No. 4405 "FINISHER NVM DATA STORE" → and then
enter "43534" to read and save the NV data from the Finisher onto the FRAM on the ComColor Engine Control
PCB.
(2) Replace the Finisher PWB with a new part.
(3) Install the latest version of the firmware software in the Finisher.
The Multi-purpose Finisher machine firmware is included in the ComColor machine firmware.
Therefore, the Finisher machine firmware is installed in the Finisher the same way as it is for the ComColor
main unit.
(4) Activate Test Mode No.
data back into the Finisher PWB.
4406 "FINISHER NVM DATA RE-STORE" → and then enter 50315
[ 24-15 ]
Multifunction Finisher II (option)
"FINISHER NVM PARAMETER
to write the NV