Test Modes
Data Editing (D)
No. Process Name
MM Low Temperature Stop Mode
6624
Selection
MM Eject Elevation Belt Temporary
6625
Stop Timing (Manual)
MM Flap Gluing Eject Non Arrival
6626
Jam Timing (162x229mm-3 fold)
MM Flap Gluing Eject Non Arrival
6627
Jam Timing (US-4 fold)
MM Eject Elevation Edge Non
6628
Arrival Jam Timing (235x120mm)
MM Eject Elevation Edge Non
6629
Arrival Jam Timing (162x229mm)
MM Eject Elevation Edge Non
6630
Arrival Jam Timing (US)
MM Guide (Body) Remaining Jam
6633
Timing (A4)
MM Guide (Body) Remaining Jam
6634
Timing (B5)
MM Guide (Body) Remaining Jam
6635
Timing (Letter)
MM Guide (Body) Remaining Jam
6636
Timing (Legal)
MM Guide (Form) Remaining Jam
6637
Timing (235x120mm)
MM Guide (Form) Remaining Jam
6638
Timing (162x229mm)
MM Guide (Form) Remaining Jam
6639
Timing (US)
6641 MM Guide Non Arrival Jam Timing
MM Form Receive Non Arrival Jam
6642
Timing
MM Form Registration Non Arrival
6686
Jam Timing
6690 MM Gluing Non Arrival Jam Timing
MM Compile Eject Remaining Jam
6691
Timing (235x120mm)
MM Compile Eject Remaining Jam
6692
Timing (162x229mm)
MM Compile Eject Remaining Jam
6693
Timing (US)
MM Flap Gluing Eject Non Arrival
6694
Jam Timing (235x120mm)
MM Form Horizontal Position Non
6695
Arrival Jam Timing
MM Eject Elevation Belt Temporary
6698
Stop Time (Low Temperature 1)
MM Eject Elevation Belt Temporary
6699
Stop Time (Low Temperature 2)
Rev.1.00
OPTIONS / Mail Maker
Default Unit/Range Description
Select MM Low Temperature Stop Mode.
0
0: Automatic (Stop time determined by ambient temperature)
1: Manual (Stop time will not determined by ambient temperature)
Adjust stop time of the MM Eject Elevation Belt for gluing
55
0-600ms
performance improvement. (When TM6624 set as 1)
260
0-1000ms
Adjust an add time on non arrival jam detection by the MM
Flap Gluing Eject Sensor.
222
0-1000ms
74
0-1000ms
Adjust an add time on non arrival jam detection by the MM
58
0-1000ms
Eject Elevation Edge Sensor.
74
0-1000ms
99
0-1000mm
86
0-1000mm
Adjust an add time on remaining jam detection by the MM
Guide Sensor.
94
0-1000mm
119
0-1000mm
100
0-1000mm
Adjust an add time on remaining jam detection by the MM
130
0-1000mm
Guide Sensor.
100
0-1000mm
Adjust an add time on non arrival jam detection by the MM
47
0-1000mm
Guide Sensor.
Adjust an add time on non arrival jam detection by the MM
52
0-1000mm
Form Receive Sensor.
Adjust an add time on non arrival jam detection by the MM
185
0-1000mm
Form Registration Sensor.
Adjust an add time on non arrival jam detection by the MM
192
0-1000ms
Gluing Sensor.
55
0-1000mm
Adjust an add time on non arrival jam detection by the MM
79
0-1000mm
Compile Eject Sensor.
55
0-1000mm
Adjust an add time on non arrival jam detection by the MM
222
0-1000mm
Flap Gluing Eject Sensor.
Adjust number of pulse on non arrival jam detection by the
688
1-30000pulse
MM Form Horizontal HP Sensor.
Adjust MM Eject Elevation Belt temporary stop time to
75
0-600ms
gluing performance improvement at low temperature.
Adjust MM Eject Elevation Belt temporary stop time to
75
0-600ms
gluing performance improvement at ultra low temperature.
[ 16-120 ]