Riso ComColor X1 series Technical Manual page 631

Hide thumbs Also See for ComColor X1 series:
Table of Contents

Advertisement

Test Modes
5-3-3. Unit Checking (U)
Unit Checking (U)
5400
Scanner Test Print
Prints a test pattern generated by the scanner.
RGB gradation data generated by the CCD board is converted to a CMYK image and printed.
Uses the resolution set in 05700 (test operation resolution setting).
Uses the size set in 05701 (test operation size setting).
Paper for printing is transferred from the paper feed tray. Finishing is not performed.
5405
Scanner Front LED
Illuminates the scanner front LEDs.
LED (green) / LED (red) (OFF: 0 / ON: 1)
Repeats this sequence: 0/0 → 1/0 → 0/1 → 1/1 → 0/0
5406
Scanner Profi le Mode
Executes scanner profi ling mode.
Profi ling is performed as follows (fi rst time).
• Prepares to record the white level adjustment value
• Transitions to recording the white level adjustment value
• Records the white level adjustment value (fi rst time)
• Performs white shading
Profi ling is subsequently performed as follows (second time).
• Records the white level adjustment value (second time)
• Performs white shading
• Updates the profi le
5409
Scanner PRMTR Print
Prints a list of test numbers and setting values for tests with values that have been changed from the defaults.
The number and setting values of scanner-related tests are printed with serial number, scanner fi rmware version, AF fi rmware
version, and setting values changed from the defaults.
The test number and setting values are transmitted as ASCII strings.
Test numbers are fi ve digits, as are setting values. Numbers and setting values are separated by a comma, and tests are
separated by line breaks.
Line breaks when printing are determined by the controller.
5410
FB Scan 1 Cycle
Activates the FB scanner for one cycle. (Return to home position → shading → scanning → return to home position.)
Scans at the resolution set in 05700 (test operation resolution setting).
Scans at the size set in 05701 (test operation size setting).
Test speed set in 05702 (test operation speed setting).
Image data is not output.
5411
FB Scan RPT Cycle
Continuously performs the operations as specifi ed in 05410 (FB scanning, 1 cycle).
When the test stops, FB scanning stops and the carriage returns to the home position.
5412
Carriage HP Return
Moves the scanner carriage to the home position.
5413
Lamp Change Position
After the carriage is moved to the home position, it is moved to the position for lamp replacement.
Lamp replacement position: 31.5 mm from the home position, toward the AF side.
5414
Carriage Lock Position
After the carriage is moved to the home position, it is moved to the locked position during auto startup.
Locked position: 8.5 mm from the home position, toward the AF side.
5415
Scanner Lock Release
Moves the carriage in the locked position to the home position.
5430
AF Scan Repeat Cycle
Performs continuous AF scanning for as many cycles as there are loaded originals. (Return to home position → shading →
move to AF scanning position → scanning.)
Uses setting values from 05700 (test operation resolution setting).
Uses setting values from 05701 (test operation size setting).
Uses setting values from 05702 (test operation speed setting).
Uses setting values from 05703 (test operation AF scanning settings).
Image data is not output.
Rev.1.00