Multifunction Finisher II (option)
2. Disassembly
2-1. Removing the Set Clamp
(1) Remove the Spring, and detach the Spring Bracket. (1 screw)
Remove the E-ring and the Gear
(2) Remove the two E-ring and dismount the gear.
(3) Remove the Set Clamp together with the shaft by sliding toward the rear.
> When reinstalling the gear, align the Gear teeth on the Cam with the opening in the flange, as shown in the
photograph.
In this step, make sure the flange section of the Gear and Cam are positioned on the outside.
Set Clamp
Remove the Spring and Spring Bracket
[ 24-66 ]
Match the Gear and Cam to the
opening of the flange