Riso ComColor X1 series Technical Manual page 901

Hide thumbs Also See for ComColor X1 series:
Table of Contents

Advertisement

Multifunction Finisher II (option)
< With staple >
(1) Perform printing or print test pattern to check for fold position deviation and staple position deviations.
• Dimension A and dimension B in the diagram must be equal.
• The staple position must align with the fold position.
> Check the staple position deviation by determining whether the staples are on the fold of the papers.
TOP
BOTTOM
(2) If fold position or staple position deviations are noticed, adjust the Test Mode parameter settings.
< For the actual adjustment procedure, refer to the next page.>
> The Test Mode Numbers differ for number of sheets per booklet, paper size, fold position adjustment and
staple position adjustment.
• In the case of A > B, reduce the Test Mode parameter setting. In the case of A < B, increase the Test Mode
parameter setting.
Value of <1> changes the folding position 0.1 mm → the difference between A and B would then be 0.2 mm.
• If the staple positions are shifted too far up on the paper as shown in the diagram, reduce the Test Mode
parameter setting.
Value of <1> changes the stapling position 0.1 mm.
(3) Perform the adjustments in the following sequence:
> Be sure to complete the staple position adjustment before performing the fold position adjustment.
The staple position should be adjusted to the fold, in regardless to the fold position on the paper.
< The staple position will automatically follow the fold position when the fold position is adjusted the next.>
Step 1: Adjust the Staple positions for 2 sheets. <Separate adjustment for paper size above B4 or smaller.>
Step 2: Adjust the Fold position for 2 sheets. <Separate adjustment for paper size above B4 or smaller.>
Step 3: Adjust the Staple positions for 15 sheets. <Separate adjustment for paper size above B4 or smaller.>
• The Staple and Fold positions for 3 to 14 sheets will automatically be adjusted when above 3 adjustments
are made.
(4) Though the adjustments by above (3) automatically adjusts the Staple and Fold positions for 3 or more sheets,
make separate fine adjustments (staple positions and/or fold positions) as needed for 3 sheets and above.
< Refer to the Next Page for the list of the Test Modes.>
FRONT
[ 24-86 ]
REAR
STAPLE:
The staples are shifted too far up on the
paper on this drawing.
Eject direction
x1 series ComColor (Revision 0.9)