Upper Transfer Out Sensor (Switchback Unit B); Upper Transfer Roller 6 (Switchback Unit B) - Riso ComColor X1 series Technical Manual

Hide thumbs Also See for ComColor X1 series:
Table of Contents

Advertisement

2-10. Upper Transfer OUT Sensor (Switchback Unit B)

1. Turn OFF the machine power and disconnect the power cable from the power source.
2. Remove the switchback unit B.
3. Remove the OUT sensor assembly. (W sems screw 3x6 (1 pc))
4. Remove the upper transfer OUT sensor. (Pan-head screw 3x14 (1 pc))
Note: After the replacement, check the operation by test mode 1107 (upper transfer OUT sensor).

2-11. Upper Transfer Roller 6 (Switchback Unit B)

1. Turn OFF the machine power and disconnect the power cable from the power source.
2. Remove switchback unit B.
3. Remove the pulley. (6 mm dia. E-ring (1 pc))
4. Remove the metal bushing (2 pcs). (6 mm dia. E-ring (2 pcs))
5. Remove upper transfer roller 6.
< FRONT >
Upper transfer roller 6
(Refer to the instructions in this Chapter.)
(Refer to the instructions in this Chapter.)
[ 10-13 ]
Switchback Section
< REAR >
Upper transfer OUT sensor
ComColor Series (Revision 2.4)