Fb Unit; Original Set Section - Riso ComColor X1 series Technical Manual

Hide thumbs Also See for ComColor X1 series:
Table of Contents

Advertisement

HS5000 Scanner (option)

2. FB Unit

2-1. Original Set Section

Setting the original
• Place the original on the stage glass and close the stage cover.
• Unlike the AF unit in which the original is placed on the center of the unit, the original is placed flat against the top
corner of the stage glass.
• If the original is set on both the AF unit and stage glass, the original on the AF unit is scanned first.
• The detection of the original on the FB stage glass is done by the original detection sensor.
• The stage cover open status is detected by two separate sensors.
• The stage cover sensor detects whether the stage cover is fully closed or not.
• The stage cover angle sensor detects the stage cover at a half opened (closed) position, and the original size is
checked when this sensor is triggered.
Original size detection
• The six original size detection sensors looks at the original on the stage glass and check the original size when
the stage cover angle sensor is triggered.
• The combination of the detection status of these six sensors determine the original size, as shown on the table
given below.
Original detection
sensor
Original size / Sensor
A5
A5R
A4R
A4
A3
B5R
B5
B4
LETTER-R
LETTER
LEGAL
LEDGER
Original size detection sensors
1
2
3
4
○ ○ ○
○ ○
○ ○ ○ ○ ○ ○
○ ○
○ ○
○ ○ ○ ○ ○
○ ○ ○
○ ○
○ ○ ○ ○
○ ○ ○ ○ ○ ○
[ 20-4 ]
5
6
x1 series ComColor (Revision 0.9)