HS5000 Scanner (option)
AF Post separation sensor
(1) Detach the AF Post separation sensor assembly from the AF unit. (P-tight bind head screw 3x10 (1 pc).
(2) Detach the grounding spring.
AF Post separation
sensor assembly
Grounding spring
(3) Remove the AF Post separation sensor from the assembly.
(4) Unplug the connector. (1 pc)
Caution in replacing the AF Post separation sensor:
Push the sensor firmly against the the mounting bracket and fix in position by a screw (W-sems screw 3x8 (1
pc)).
[ 20-30 ]