5-4-3. Unit Checking (U)
Unit Checking (U)
3415
HCF P-F Tray Paper Length (Wide)
For paper size detection, set 297mm A/D value.
3416
HCF P-F Tray Paper Length (Narrow)
For paper size detection, set 105mm A/D value.
3417
HCF P-F Tray Move to Upper Limit Position
Rotate the elevator motor and stops the P- F Tray at upper limit position.
Then execute the follow up action in the upper limit position.
Upper limit position can be adjusted by the Test Mode [P-F Tray Upper Limit Position]
3418
HCF P-F Tray Move to Lower Limit Position
Rotate the elevator motor and stops the P- F Tray at lower limit position.
3419
HCF HCF Middle Entrance Sensor Automatic Light Intensity Adjustment
Auto adjustment of the intensity of light for the HCF Middle Entrance Sensor.
3450
HCF Nip Release Unit 1 Cycle Action
1. HCF nip release unit move to the nip position
2. HCF nip release unit move to the release position
If the unit is not in correct position, move to nip position again and do above cycle.
3452
HCF Nip Release Unit Release Position
Move the HCF nip release unit to the release position.
3453
HCF Nip Release Unit Nip Position
Move the HCF nip release unit to the nip position.
3454
HCF P-F Tray Maintenance Position
Move the HCF P-F Tray to upper limit position, then lower the P-F Tray to the 10% paper remaning position.
5-4-4. Initialization (I)
Initialization (I)
3525
HCF EEPROM Initialization
All data in HCF EEPROM are put back to default.