Riso ComColor X1 series Technical Manual page 460

Hide thumbs Also See for ComColor X1 series:
Table of Contents

Advertisement

Type
S98: Hardware error
!!System Error!!
Display
Reboot by press the Sub Power Key
If recovery has failed, call service.
There is a discrepancy exceeding 5V between the drive voltage acquired from rows of head nozzles (A)
and the drive voltage of rows of head nozzles as confi gured in the register (B).
When the variation code is 1, (A) and (B) are the 1 side, and when it is 2, (A) and (B) are the 2 side.
Details in Common
The HDR sub-CPU detected a divergence of the drive voltage acquired from rows of head nozzles (C) from
the drive voltage as confi gured.
When the variation code is 3, (C) is the 1 side, and when it is 4, (C) is the 2 side.
Clear
Turn OFF the printer. (Turn OFF the printer through sub power key.)
Point
Description
2230-2235 1-4
Black #1-6 head
2236-2241 1-4
Cyan #1-6 head
2242-2247 1-4
Magenta #1-6 head
2248-2253 1-4
Yellow #1-6 head
Type
S98: Hardware error
!!System Error!!
Display
Reboot by press the Sub Power Key
If recovery has failed, call service.
Drive waveform confi guration could not be completed correctly for head nozzles (A).
Details in Common
When the variation code is 1, (A) is the 1 side, and when it is 2, (A) is the 2 side.
Clear
Turn OFF the printer. (Turn OFF the printer through sub power key.)
Point
Description
2260-2265 1-2
Black #1-6 head
2266-2271 1-2
Cyan #1-6 head
2272-2277 1-2
Magenta #1-6 head
2278-2283 1-2
Yellow #1-6 head
Type
S98: Hardware error
!!System Error!!
Display
Reboot by press the Sub Power Key
If recovery has failed, call service.
Head nozzles (A) were not in a state enabling drive waveform confi guration.
Details in Common
When the variation code is 1, (A) is the 1 side, and when it is 2, (A) is the 2 side.
Clear
Turn OFF the printer. (Turn OFF the printer through sub power key.)
Point
Description
2290-2295 1-2
Black #1-6 head
2296-2301 1-2
Cyan #1-6 head
2302-2307 1-2
Magenta #1-6 head
2308-2313 1-2
Yellow #1-6 head
Type
S98: Hardware error
!!System Error!!
Display
Reboot by press the Sub Power Key
If recovery has failed, call service.
Head nozzles (A) were not in a state enabling drive waveform confi guration.
Details in Common
When the variation code is 1, (A) is the 1 side, and when it is 2, (A) is the 2 side.
Clear
Turn OFF the printer. (Turn OFF the printer through sub power key.)
Point
Description
2320-2325 1-2
Black #1-6 head
2326-2331 1-2
Cyan #1-6 head
2332-2337 1-2
Magenta #1-6 head
2338-2343 1-2
Yellow #1-6 head