Belt Shaft Fg Sensor Assembly (Encoder); Transfer Belt - Riso ComColor X1 series Technical Manual

Hide thumbs Also See for ComColor X1 series:
Table of Contents

Advertisement

2-6. Belt Shaft FG Sensor Assembly (Encoder)

Note: Do not remove unless the sensor is actually damaged.
1. Turn OFF the machine power and disconnect the power cable from the power source.
2. Remove the BP unit. (Refer to the instructions for removal.)
3. Disconnect the FG Sensor wire connector. (1 pc)
4. Remove the reuse band. (1 pc)
5. Remove the belt shaft FG sensor assembly.
(W sems screw 3x30 (1 pc) and round tip IT3C screw 4x8 (1 pc))
Note: After replacement, check operation by test mode 1100 (belt shaft FG sensor).
Connector

2-7. Transfer Belt

Caution: (1) Do not remove the front frame of the BP Unit.
(2) Do not separate the encoder from the Driven roller.
1. Turn OFF the machine power and disconnect the power cable from the power source.
2. Remove the BP unit. (Refer to the instructions for removal.)
3. Remove the BP front cover. (Binding screw 4x8 (3 pcs))
4. Remove the Transfer belt motor assembly. (See Section 2-1.)
5. Affix 4 mm diameter JIG shaft through the front and rear Tension roller assemblies. (2 pcs)
the tension of the transfer belt.>
<< FRONT >>
4 mm dia. JIG shaft
Front tension roller assembly
Encoder assembly
Reuse band
<< REAR >>
Rear tension roller assembly
4 mm dia. JIG Shaft
REFERENCE PHOTOGRAPH
[ 7-15 ]
BP Section
<This is to release
4 mm dia. JIG shaft
ComColor Series (Revision 2.4)

Advertisement

Table of Contents
loading

Table of Contents