Riso ComColor X1 series Technical Manual page 634

Hide thumbs Also See for ComColor X1 series:
Table of Contents

Advertisement

No. Process Name
5715 Scanner Lock/Unlock
5718 R0/Offset Adjustment
5719 G0/Offset Adjustment
5720 B0/Offset Adjustment
5721 R1/Offset Adjustment
5722 G1/Offset Adjustment
5723 B1/Offset Adjustment
5724 R0/Gain Adjustment
5725 G0/Gain Adjustment
5726 B0/Gain Adjustment
Default
Unit/Range
0: Operation
permitted
0
1: Operation
prohibited
0
0-12
0
0-12
0
0-12
0
0-12
0
0-12
0
0-12
0
0-127
0
0-127
0
0-127
[ 16-91 ]
Description
Specifi es whether scanner operation is locked. (Operation
permitted/operation prohibited)
When you specify 1 (operation prohibited), the scanner
does not function except for downloads in normal mode (FB
or AF), AF initialization, and test mode 0571 5 (scanner lock
setting).When scanner operations other than downloads in
normal mode (FB or AF), AF initialization, and test mode
0571 5 (scanner lock setting) are requested, error U06-4330
occurs, indicating that the scanner is locked and operation
is prohibited.
Specifi es the offset adjustment value for R0 data.
The setting value is stored in EEPROM.
During offset adjustment, this setting value is used.
After offset adjustment, the setting value is updated with the
value representing the results of adjustment setting value
stored in EEPROM is also updated.
Specifi es the offset adjustment value for G0 data.
The setting value is stored in EEPROM.
During offset adjustment, this setting value is used.
After offset adjustment, the setting value is updated with the
value representing the results of adjustment setting value
stored in EEPROM is also updated.
Specifi es the offset adjustment value for B0 data.
The setting value is stored in EEPROM.
During offset adjustment, this setting value is used.
After offset adjustment, the setting value is updated with the
value representing the results of adjustment setting value
stored in EEPROM is also updated.
Specifi es the offset adjustment value for R1 data.
The setting value is stored in EEPROM.
During offset adjustment, this setting value is used.
After offset adjustment, the setting value is updated with the
value representing the results of adjustment setting value
stored in EEPROM is also updated.
Specifi es the offset adjustment value for G1 data.
The setting value is stored in EEPROM.
During offset adjustment, this setting value is used.
After offset adjustment, the setting value is updated with the
value representing the results of adjustment setting value
stored in EEPROM is also updated.
Specifi es the offset adjustment value for B1 data.
The setting value is stored in EEPROM.
During offset adjustment, this setting value is used.
After offset adjustment, the setting value is updated with the
value representing the results of adjustment setting value
stored in EEPROM is also updated.
Specifi es the gain adjustment value for R0 data.
The setting value is stored in EEPROM.
During gain adjustment, this setting value is used.
After gain adjustment, the setting value is updated with the
value representing the results of adjustment. The setting
value stored in EEPROM is also updated.
Specifi es the gain adjustment value for G0 data.
The setting value is stored in EEPROM.
During gain adjustment, this setting value is used.
After gain adjustment, the setting value is updated with the
value representing the results of adjustment. The setting
value stored in EEPROM is also updated.
Specifi es the gain adjustment value for B0 data.
The setting value is stored in EEPROM.
During gain adjustment, this setting value is used.
After gain adjustment, the setting value is updated with the
value representing the results of adjustment. The setting
value stored in EEPROM is also updated.
Test Modes
Rev.1.00

Advertisement

Table of Contents
loading

Table of Contents