Riso ComColor X1 series Technical Manual page 635

Hide thumbs Also See for ComColor X1 series:
Table of Contents

Advertisement

Test Modes
Data Editing (D)
No. Process Name
5727 R1/Gain Adjustment
5728 G1/Gain Adjustment
5729 B1/Gain Adjustment
5730 AF Scan Horizonta Position
5731 AF Scan Start Position (F)
5732 AF Scan Start Position (B)
5733 AF Scan Elongation (F)
5734 AF Scan Elongation (B)
5735 AF Scan Carriage Position
Rev.1.00
Default
Unit/Range
0
0-127
0
0-127
0
0-127
128
81-175
0
(-40 - 40)
0
(-40 - 40)
Setting
value of
(-20 - 20)
05903
Setting
value of
(-20 - 20)
05904
Setting
value of
98-158
05905
[ 16-92 ]
OPTIONS / Scanner
Description
Specifi es the gain adjustment value for R1 data.
The setting value is stored in EEPROM.
During gain adjustment, this setting value is used.
After gain adjustment, the setting value is updated with the
value representing the results of adjustment. The setting
value stored in EEPROM is also updated.
Specifi es the gain adjustment value for G1 data.
The setting value is stored in EEPROM.
During gain adjustment, this setting value is used.
After gain adjustment, the setting value is updated with the
value representing the results of adjustment. The setting
value stored in EEPROM is also updated.
Specifi es the gain adjustment value for B1 data, which is
stored in EEPROM.
During gain adjustment, this setting value is used.
After gain adjustment, the setting value is updated with the
value representing the results of adjustment. The setting
value stored in EEPROM is also updated.
Adjusts the lateral position for originals scanned using the
AF.
Images are moved as follows. Minimum value (81): -2.0 mm
relative to the reference position. Maximum value (17 5):
+2.0 mm relative to the reference position.
Negative values move images right, and positive values
move images left.
Adjusts the starting position (the amount to skip before
scanning) of the top surface for originals scanned using the
AF.
Images are moved as follows. Minimum value (-40): -4.0
mm relative to the reference position. Maximum value (40):
+4.0 mm relative to the reference position.
Negative values move images toward the trailing edge,
positive values move images toward the leading edge.
Adjusts the starting position (the amount to skip before
scanning) of the bottom surface for originals scanned using
the AF.
Images are moved as follows. Minimum value (-40): -4.0
mm relative to the reference position. Maximum value (40):
+4.0 mm relative to the reference position.
Negative values move images toward the leading edge, and
positive values move images toward the trailing edge.
Adjusts the speed (image stretching/shrinkage) for the top
surface for originals scanned using the AF.
Adjusts the speed of the AF read pulse motor.
The speed is adjusted as follows. Minimum value (-20):
-2.0% relative to the reference speed. Maximum value (20):
+2.0% relative to the reference speed.
Negative values stretch images, and positive values shrink
them.
Adjusts the speed (image stretching/shrinkage) for the
bottom surface for originals scanned using the AF.
Adjusts the speed of the AF read pulse motor.
The speed is adjusted as follows. Minimum value (-20):
-2.0% relative to the reference speed. Maximum value (20):
+2.0% relative to the reference speed.
Negative values stretch images, and positive values shrink
them.
Adjusts the carriage position for originals scanned using the
AF.
Images are moved as follows. Minimum value (74): -4.1 mm
relative to the reference position. Maximum value (182):
+4.1 mm relative to the reference position.
Negative values move images toward the trailing edge,
positive values move images toward the leading edge.