Multifunction Finisher II (option)
2-4. Removing the Tamper Unit
(1) Remove the Booklet Unit from the Finisher main unit. (Refer to page No. 24-21 of this Chapter.)
(2) Fully open the Tampers at both ends before initiating the removal procedure.
> If the Knife is extended out while the Tampers are positioned toward the inside, the Knife contacts the Tampers
and may cause the Tampers to break and Knife to deform.
(3) Remove 1 screw (wood screw) from the shaft of the 4a Knob and remove the 4a Knob.
4a Knob
(4) Remove one E-ring and bearing from the shaft in which the 4a Knob was removed. Then by removing the
four mounting screws (ordinary screws), detach the Front Cover of the Booklet Unit.
Mounting screws
(5) Remove the two mounting screws of the Motor cover plate (on the rear of the unit) and remove the Motor
cover plate.
Front Cover
Motor cover plate
[ 24-76 ]