5-8-6. Data Editing (D)
Data Editing (D)
No. Process Name
PB Cool Down Start Time
7616
Setting
PB Clamp Body Insert
7618
Horizontal Position Adjustment
PB Clamp Gluing Horizontal
7619
Position Adjustment
PB Clamp Blade Horizontal
7620
Position Adjustment
PB Clamp Forming Horizontal
7621
Position Adjustment
PB Clamp Exit Horizontal
7622
Position Adjustment
PB Clamp Body Insert Height
7623
Adjustment
PB Clamp Gluing Height
7624
Adjustment
PB Clamp Blade Height
7625
Adjustment
PB Clamp Forming Height
7626
Adjustment
PB Cover Length Measurement
7627
Resolution
PB Cover Forming Position
7628
Adjustment 1
PB Cover Forming Position
7629
Adjustment 2
PB Cover Forming Position
7630
Adjustment 3
PB Cover Forming Position
7631
Adjustment 4
PB Cover Forming Position
7632
Adjustment 5
PB Cover Forming Position
7633
Adjustment 6
PB Cover Forming Position
7634
Adjustment 7
PB Cover Forming Position
7635
Adjustment 8
PB Cover Forming Position
7636
Adjustment 9
PB Cover Forming Position
7637
Adjustment 10
PB Cover Forming Position
7638
Adjustment 11
PB Cover Forming Position
7639
Adjustment 12
7640 PB Back Glue Stock Value
Rev.1.00
OPTIONS / Perfect Binder
Default Unit/Range
Description
10
10-60minute
Set time period for the system goes into cool down process.
Adjust value for the clamp move horizontally to reach to
0
(-150 - 150)
body insert position. (1=0.1mm)
Adjust value for the clamp move horizontally to reach to
0
(-150 - 150)
gluing position. (1=0.1mm)
Adjust value for the clamp move horizontally to reach to
0
(-150 - 150)
blade position. (1=0.1mm)
Adjust value for the clamp move horizontally to reach to
0
(-150 - 150)
forming position. (1=0.1mm)
Adjust value for the clamp move horizontally to reach to exit
0
(-150 - 150)
position. (1=0.1mm)
Adjust value for the clamp move up/down direction to reach
0
(-25 - 25)
to body insert height. (1=0.1mm)
Adjust value for the clamp move up/down direction to reach
0
(-40 - 40)
to gluing height. (1=0.1mm)
Adjust value for the clamp move up/down direction to reach
0
(-30 - 30)
to blade height. (1=0.1mm)
Adjust value for the clamp move up/down direction to reach
0
(-40 - 40)
to forming height. (1=0.1mm)
Measurement resolution for calculating PB cover length.
4050
4000-4100pulse
(1pulse = 0.01um)
Adjust value of moving the cover to forming position. [A4
0
(-150 - 150)
size-Thickness: between 0.1mm and 4.9mm] (1=0.1mm)
Adjust value of moving the cover to forming position. [A4
0
(-150 - 150)
size-Thickness: between 5.0mm and 14.9mm] (1=0.1mm)
Adjust value of moving the cover to forming position. [A4
0
(-150 - 150)
size-Thickness: Over 15.0mm] (1=0.1mm)
Adjust value of moving the cover to forming position. [B5
0
(-150 - 150)
size-Thickness: between 0.1mm and 4.9mm] (1=0.1mm)
Adjust value of moving the cover to forming position. [B5
0
(-150 - 150)
size-Thickness: between 5.0mm and 14.9mm] (1=0.1mm)
Adjust value of moving the cover to forming position. [B5
0
(-150 - 150)
size-Thickness: Over 15.0mm] (1=0.1mm)
Adjust value of moving the cover to forming position. [A5
0
(-150 - 150)
size-Thickness: between 0.1mm and 4.9mm] (1=0.1mm)
Adjust value of moving the cover to forming position. [A5
0
(-150 - 150)
size-Thickness: between 5.0mm and 14.9mm] (1=0.1mm)
Adjust value of moving the cover to forming position. [A5
0
(-150 - 150)
size-Thickness: Over 15.0mm] (1=0.1mm)
Adjust value of moving the cover to forming position. [Letter
0
(-150 - 150)
size-Thickness: between 0.1mm and 4.9mm] (1=0.1mm)
Adjust value of moving the cover to forming position. [Letter
0
(-150 - 150)
size-Thickness: between 5.0mm and 14.9mm] (1=0.1mm)
Adjust value of moving the cover to forming position. [Letter
0
(-150 - 150)
size-Thickness: Over 15.0mm]
Factor to calculate the accumulated amount of the back
90
50-300
glue.