Maintenance-Object Repair Procedures
Table 8-677. Test #142 Major Alarm Inquiry Test — Continued
Error
Test
Code
Result
Description / Recommendation
FAIL
If the UDS1 connects to a line-side terminating device (for example, a PRI
(cont'd)
terminal adapter), do the following:
1. The performance of the DS1 link between the UDS1 interface circuit pack
2. Verify that the switch DS1 and the line-side terminating device are
3. Investigate the maintenance status of the line-side terminating device.
4. Contact the vendor of the line-side terminating device to diagnose the
5. Check the physical connection of the UDS1 interface circuit pack to the
6. Replace the local UDS1 interface circuit pack and repeat the test.
PASS
No Major alarm is detected in the UDS1 Interface circuit pack.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board's translations are correct. Execute the add ds1
2. If the board was already administered correctly, check the error log to
3. If the board was found to be correctly inserted in step 1, then issue the
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
8-1764
Issue 1 May 2002
and the line-side terminating device is very poor. Enter the list
measurement ds1-log UUCSS command to read the error seconds
measurement.
administered using the same signaling mode, framing mode, and line
coding.
Refer to the 'Line-Side Terminating Device Operating Manual' for
information.
equipment.
terminating device, and check the premise distribution system (or the
intra-premise wiring) for physical connection failures.
UUCSS command to administer the UDS1 interface if it is not already
administered.
determine whether the board is hyperactive. If so, the board is shut
down. Reseating the board will re-initialize it.
busyout board command.
Continued on next page