UDS1-BD (UDS1 Interface Circuit Pack)
Table 8-677. Test #142 Major Alarm Inquiry Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test was not received within the allowable time period. This
may be due to hyperactivity. Error Type 1538 in the error log indicates
hyperactivity. The hyperactive circuit pack is out of service, and one or more
of the following symptoms may be exhibited.
1. The UDS1-BD tests (such as Test #138 and #139) are aborting with error
2. The tests run on the ports of this circuit pack are returning a no-board
3. A busyout or a release command has no effect on the test results.
4. A list config command shows that the circuit pack and its ports are
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
If the UDS1 connects to a T1 network facility or to another switch, do the
following:
1. The performance of the DS1 link between the UDS1 interface circuit pack
2. Verify that both endpoints of the DS1 link are administered using the
3. Contact T1 Network Service or the technician at the remote switch to
4. Check the physical connectivity of the UDS1 interface circuit packs and
5. Replace the local UDS1 interface circuit pack, and repeat the test.
555-233-143
code 2000.
result.
properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated from the system,
and all of its trunks are placed into the out-of-service state. The system
will try to restore the circuit pack within 15 minutes. When no faults are
detected for 15 minutes, the UDS1 interface circuit pack is restored to
normal operation. Every UDS1 Interface trunk is then returned to the
in-service state. Hyperactivity is often caused by the associated facility.
In such a case, faults (such as slips, misframes, or blue alarms) would
be entered in the error log. In addition, many hardware errors would be
logged against the associated trunk circuits. If the facility is OK and the
error occurs again after 15 minutes, replace the circuit pack.
and the remote DS1 endpoint is very poor. Enter the list measurement
ds1-log UUCSS command to read the error seconds measurement.
same signaling mode, framing mode, and line coding.
diagnose the equipment.
the cable.
Continued on next page
Issue 1 May 2002
8-1763