Maintenance-Object Repair Procedures
Control Channel Loop-Around Test (#52)
This test queries the circuit pack for its code and vintage and verifies its records.
Table 8-670. Test #52 Control Channel Loop-Around Test
Error
Test
Code
Result
Description / Recommendation
None,
ABORT
System resources required for this test are not available.
2100
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The circuit pack failed to return the its code or vintage.
1. Retry the command up to 5 times.
2. If the problem continues and if the circuit pack is a port circuit pack, replace
3. Retry the command several times up to 5 times.
PASS
Communication with this circuit pack is successful.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board's translations are correct. Execute the add ds1
2. If the board was already administered correctly, check the error log to
3. If the board was found to be correctly inserted in step 1, then issue the
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
8-1734
Issue 1 May 2002
the circuit pack.
UUCSS command to administer the UDS1 interface if it is not already
administered.
determine whether the board is hyperactive. If this is the case, the board is
shut down. Reseating the board will re-initialize it.
busyout board command.