UDS1-BD (UDS1 Interface Circuit Pack)
ad. Error Type 3901 — Provides status information about a Far CSU
Loopback test. The value in the Aux Data field indicates the status of the
loop-back test.
Aux Data
1
2
3
4
ae. Error Type 3902 — Provides status information about a One-Way Span
test. The value in the Aux Data field indicates the status of the span test.
Aux Data
1
2
3
4
af. Error Type 3999 — Indicates that the circuit pack sent a large number of
control channel messages to the switch within a short period of time. If
Error Type 1538 is also present, then the circuit pack was taken
out-of-service due to hyperactivity. If Error Type 1538 is absent, then the
circuit pack was not taken out-of-service, but it has generated 50% of the
messages necessary to be considered hyperactive. This may be
completely normal during heavy traffic periods. However, if this error type
is logged when the circuit pack is being lightly used, it may indicate a
problem with the circuit pack or the equipment attached to it.
555-233-143
Test Status
Currently running
Failed because loop back could not be activated
Failed because test pattern could not be detected
Terminated
Test Status
Currently running
Failed because test could not be activated
Test pattern was not received from the far end
Terminated
Issue 1 May 2002
8-1731