Change Synchronization - Avaya S8700 Maintenance Manual

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Commands

change synchronization

This command is destructive .
This command changes the synchronization source to the system.
Table 7-10. change synchronization command parameters
Action/ Object
Qualifier
change
synchronization
cabinet*
number
Cabinet number only applies to S8700 IP Connect configurations
Output
The following example shows the output for the change synchronization
command for an S8700 IP Connect configuration.
change synchronization 1
SYNCHRONIZATION SOURCE (circuit pack location)
CIRCUIT PACKS AVAILABLE FOR SYNCHRONIZATION
Location
Type
Name
01B05
DS1
GERT<>Lulu
01A08
DS1
Gertrude <> 5E
01A09
DS1
GERT Loop 414
01B02
DS1
gertrude <> st1
NOTE: DS1 and BRI TRUNK sources result in stratum 4, type II synchronization
7-72
Issue 1 May 2002
Qualifier Description
1-64
SYNCHRONIZATION PLAN
CABINET 1
Stratum: 4
Primary: 01B02
Secondary: 01A08
Slip
n
y
y
y
Permissions
Defaults
init
none
inads
craft
Location
Type
Name
Feature
Interactions
none
Page
1 of
2
Slip
555-233-143