TCNT value
H'0180
H'0160
H'0010
H'0005
H'0000
TIOCA
TGRA
TIOCB
TGRB
11.4.2
Synchronous Operation
In synchronous operation, the values in multiple TCNT counters can be rewritten simultaneously
(synchronous presetting). Also, multiple of TCNT counters can be cleared simultaneously
(synchronous clearing) by making the appropriate setting in TCR.
Synchronous operation enables TGR to be incremented with respect to a single time base.
Channels 0 to 5 can all be designated for synchronous operation.
Example of Synchronous Operation Setting Procedure: Figure 11.10 shows an example of the
synchronous operation setting procedure.
Rev. 1.0, 09/01, page 536 of 904
H'0005
Figure 11.9 Example of Input Capture Operation
Counter cleared by TIOCB
input (falling edge)
H'0160
H'0180
Time
H'0010