Start of reception
Read ORER flag in SSR
Read RDRF flag in SSR
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
No
All data received?
Clear RE bit in SCR to 0
[3]
Overrun error handling
Clear ORER flag in SSR to 0
Rev. 1.0, 09/01, page 682 of 904
Initialization
ORER = 1?
No
Error processing
(Continued below)
RDRF = 1?
Yes
Yes
<End>
Error handling
<End>
Figure 15.19 Sample Serial Reception Flowchart
[1]
SCI initialization:
[1]
The RxD pin is automatically
designated as the receive data
input pin.
[2] [3]
[2]
If a receive error occurs, read the
ORER flag in SSR, and after
performing the appropriate error
Yes
handling, clear the ORER flag to
[3]
0. Transfer cannot be resumed if
the ORER flag is set to 1.
[4]
SCI status check and receive
data read:
Read SSR and check that the
[4]
RDRF flag is set to 1, then read
the receive data in RDR and
clear the RDRF flag to 0.
Transition of the RDRF flag from
0 to 1 can also be identified by
an RXI interrupt.
[5]
Serial reception continuation
procedure:
To continue serial reception,
before the MSB (bit 7) of the
current frame is received, finish
reading the RDRF flag, reading
[5]
RDR, and clearing the RDRF flag
to 0. The RDRF flag is cleared
automatically when the DMAC or
DTC is activated by a receive-
data-full interrupt (RXI) request
and the RDR value is read.
Receive error handling: