Troubleshooting a Duplicated Server
Auxiliary Data for SYSTEM Errors 6002, 6003,
6102, and 6103
The following table shows which components are indicted by the auxiliary error
codes found by using the preceding flowchart
you have identified the faulted component, consult the section for that
maintenance object (MO).
Aux Data
4137
16389
Testing the Standby Server
The server (system's SPE) may not have had time to log errors against the failed
component that caused the spontaneous interchange. If you have progressed
through the preceding flowchart without determining the cause of interchange,
test the standby for faults by proceeding through the following steps shown in
Figure 4-3 on page
555-233-143
Implicated MO
PKT-INT
DUPINT
4-14.
(Figure 4-2 on page
4-12). Once
Issue 1 May 2002